mState_ExternalLatch

0

1 status

R

MB315210

mState_Gearing

0

1 status

R

MW31221

mState_LatchTarget

0

1 status

R

MB315413

mState_Main_Latch

0

1 status

R

MB315010

mState_MainPower

0

1 status

R

IBC0019

mState_Program1

0

1 status

R

SB005000

mState_Program2

0

1 status

R

SB005001

mState_Program3

0

1 status

R

SB005002

mState_Program4

0

1 status

R

SB005003

mState_Program5

0

1 status

R

SB005004

mState_Program6

0

1 status

R

SB005005

mState_Program7

0

1 status

R

SB005006

mState_Program8

0

1 status

R

SB005007

mState_ServoReady

0

1 status

R

IBC0014

mState_ServoRotation

0

1 status

R

IBC0013

mState_SVON

0

1 status

R

IBC0018

mTime

-2147483648

2147483647 counter

R

ML31152

mTorque_Actual

-327.68

327.67 % rated torque

R

IWC00E

mWarningOverload

0

1 status

R

MB311400

mWarningRegen

0

1 status

R

MB311401

Table 2: Parameters and System Variables

Name

Default

Minimum

Maximum

Units

R/W

Address

pGain_FeedForward

0

0

200 %

R/W OWC011

pGain_Integral_PControl

300

0

32767 mSec

R/W OWC035

pGain_PositionLoop

300

0

32767 0.1/Sec

R/W OWC010

pLimit_Integration

32767

0

32767 —

R/W OWC036

pLimit_PositioningError

0

calculated

calculated MP user units

R/W MF32120

pLimit_Speed

calculated

calculated MP user units/s

R/W MF32122

sAcceleration_Virtual

0

32767

0 Ext user units/s

2

R/W MF31076

sCamShift_Clear

0

0

1 event

W

MB312803

sCamShift_Mode

0

0

1 configuration

R/W MB312804

sCamUpdate

0

0

1 event

W

MB312604

sExternalMode

0

0

1 configuration

R/W MB310640

sHome_Offset

0

calculated

calculated MP user units

R/W MF32134

sLimit_Speed_Negative

calculated

calculated MP user units/s

R/W MF32130

Table 1: Monitors (Continued)

Name

Minimum

Maximum

Units

R/W

Address