14 latch – Yaskawa MotionWorks+ Windows Software User Manual

Page 154

Advertising
background image

Block Reference

MotionWorks+™

148

3.2.14 LATCH

Definition

This block enables or disables the registration latch capture function. It controls when
an axis position can be latched, and when it cannot. If necessary, use IF EVENT or
INPUT blocks to check for the minimum and maximum realistic latch positions to
minimize the chance of latching false registration marks on material that may have other
markings. When a latch occurs, the latch function is automatically disabled to avoid
receiving multiple latches. Check mState_Latch_Main or mState_Latch_External to
determine if the latch was captured. The axis position at the time of the latch occurrence
is stored in mPosition_Latch_External. Note: If using the LATCH TARGET block, this
block is not required to set the latch window, the LATCH TARGET block contains these
settings.

Properties

Enabled:

Select whether the latch function is enabled or disabled.

Latch Axis:

Select whether to latch the main or external encoder position
when the registration latch input signal is received for the speci-
fied axis.

Required Conditions

When using the main registration latch (External Latch Signal 3 - EXT3), the latch must
be enabled by parameter setting in the SGDH amplifier. Typically, this is accomplished
by setting parameter Pn511.3 to “6”. Regardless of the discrete input selected, the state
of the latch is stored in mState_Main_Latch. MotionWorks+

 default value for Pn511.3

is “6”. Therefore, under normal circumstances, no special configuration is necessary.
See the following table for further details.

Property

Default

Minimum

Value

Maximum

Value

Base Units

Run

Time

Enabled

True

False

True

N/A

No

Latch Axis

Main

External

Main

N/A

No

Pn511.3 Settings

Setting

Description

MW+ I/O Name

0 to 3

Sets the signal to always disabled.

Advertising