MotionWorks+™

Standardized Template Project

199

Local Output Functionality

Output

Functionality

Description

MW+ Name

All Modes

°

All Modes

°

Local_Output1

Servo Enabled

On when Servo Enabled

Local_Output2

Manual Mode

On when in Manual Mode

Local_Output3 Automatic Mode On when in Automatic Mode
Local_Output4 Homed / Homing On when homed, flashing while homing, Off otherwise

°

Manual Mode

°

Local_Output5

Jogging Fwd

Flashing when jogging forward, until max jog speed achieved, then on solid

Local_Output6

Jogging Rev

Flashing when jogging reverse, until max jog speed achieved, then on solid

Local_Output7

Homing

Flashing while homing, on solid when homed, off otherwise

Local_Output8 Applying Torque Flashing while applying torque, on solid when applied torque=requested torque

°

Automatic Mode °

Local_Output5

Index

On while indexing

Local_Output6

Gear

On while Gearing

Local_Output7

Cam

On while Camming, Flashing when engaging/disengaging camming

Local_Output8

Latch

On during latch routine

°

While Indexing °

Local_Output6

PLS

On first third of move

Local_Output7

PLS

On second third of move

Local_Output8

PLS

On last third of move

°

While Latching °

Local_Output5

PLS

On before Latch Window Starts

Local_Output6

PLS

On during Latch Window

Local_Output7

PLS

On after Latch Window Ends until default distance reached

Advertising