4
Active low input signal from S14 (CN1-44)
Sigma_EXT1
5
Active low input signal from SI5 (CN1-45)
Sigma_EXT2
6
Active low input signal from SI6 (CN1-46)
Sigma_Latch_Input
7
Sets the signal to always enabled
—
8
Sets the signal to always disabled
—
D
Active high input signal from SI4 (CN1-44)
Sigma_EXT1
E
Active high input signal from SI5 (CN1-45)
Sigma_EXT2
F
Active high input signal from SI6 (CN1-46)
Sigma_Latch_Input
9 to F
Sets the signal to always disabled
—
Pn511.3 Settings