MotionWorks+™

The Project Explorer

41

Variable Mapping

If a bit type variable is set for HMI usage, it will be mapped within the range of
MB000000 through MB02047F. This restriction will be enforced because Memobus
can only write bits in the range of MB000000 through MB04096F. When Memobus
writes bits outside of this range, the entire word is written, not just the bit, so there is a
possibility of corrupted data.

Importing an HMI Data List

Accessibility

To import an HMI data list, select:
• From the Project Menu > Data >Import HMI
• From the Project Explorer > Right click on an item in the Data folder and select

“Import.”

Import Method: If there are no variables, network, or tables in the project, the import
function will proceed without dialog for each type of item that has no existing entries. If
there are existing entries, the import will append to the list. If names already exist in the
current project, notification will be given to the user by the MW+ Importing Error dialog
box shown below.