Yaskawa MotionWorks+ Windows Software User Manual

Page 41

Advertising
background image

MotionWorks+™

The Project Explorer

35

2. Type

Select from “.cam”, “.txt”, “.dat”, “.csv”, or “Empty Table”. A CAM table is imported
from an *.cdd file and follows the cam tool format. A .csv file is an ASCII file with
data separated by commas. An empty table is either downloaded at run time or
generated within the MW+

 program with SET VARIABLE blocks.

3. Data Type

This field determines the potential magnitude of each item in the table.

4. Read Only

This field determines whether items in the table can be changed by the program at run
time.

5. File Name

For Cam (.cdd) or .csv tables, select the file from which data is imported.

6. Entries

Select the maximum number of items the table can contain. If a file is imported, the
Entries property is automatically determined by the size of the file.

7. Base Address

This field is a read only field indicating the starting register location of the table in the
controller memory. This is provided for debugging with MotionWorks™ or accessing
data via Memobus serial communication.

8. HMI Checkbox

This field is used to set data to be written to the HMI export file.

Advertising