Yaskawa MotionWorks+ Windows Software User Manual

Page 22

Advertising
background image

The Project Explorer

MotionWorks+™

16

Pn102

40

1

2000

Position Loop Gain in 1/s. This parameter is not applicable
when using MP940. See section 6.2.1 of SGDH manual.

Pn103

100

0

10000 Inertia Ratio in percentage. See sections 6.2.1 and 6.3.3 of

SGDH manual.

Pn104

40

1

2000

2nd Speed Loop Gain in Hz. This parameter is switchable with
Pn100 based on user input. This is an important component of
servo tuning, this parameter acts as the derivative gain. See
section 6.2.1 of SGDH manual.

Pn105

2000

15

51200 2nd Speed Loop Integral Time Constant in 0.01 ms. This

parameter is switchable with Pn101. This is an important com-
ponent of servo tuning. See section 6.2.1 of SGDH manual.

Pn106

40

1

2000

2nd Position Loop Gain in 1/s. This parameter is not applicable
when using MP940. See section 6.2.1 of SGDH manual.

Pn107

0

0

450

Bias in rpm. See section 6.2.4 of SGDH manual.

Pn108

7

0

250

Bias Width Addition in reference units. See section 6.2.4 of
SGDH manual.

Pn109

0

0

100

Feed Forward in percentage. This parameter is not applicable
when MP940 is used. Use pGain_FeedForward. See section
6.2.2 of SGDH manual.

Pn10A

0

0

6400

Feed-forward Filter Time Constant in 0.01ms. This parameter
is not applicable when MP940 is used. See section 5.2.5 of
SGDH manual.

Pn10B

0004

0000

2014

Gain-related Application Switches. See section 6.2.5 of SGDH
manual.

Pn10C

200

0

800

Mode Switch Torque Reference in percentage. See section
6.2.5 of SGDH manual.

Pn10D

0

0

10000 Mode Switch Speed Reference in rpm. See section 6.2.5 of

SGDH manual.

Pn10E

0

0

3000

Mode Switch Acceleration in 10rpm/s. See section 6.2.5 of
SGDH manual.

Pn10F

0

0

10000 Mode Switch Error Pulse in reference units. This parameter is

not applicable when using MP940. See section 6.2.5 of SGDH
manual.

Pn110

0012

0000

2014

Online Autotuning Switches. See section 6.3.4 of SGDH man-
ual.

Pn111

100

1

100

Speed Feedback Compensation in percentage. See section
6.2.6 of SGDH manual.

Pn200

0

0

1239

Position Control Reference Selection Switches. This parameter
is not applicable when using MP940. See section 5.2.2 of
SGDH manual.

Pn201

16384

16

16384 PG Divider in pulses per revolution. This parameter is not

applicable when using MP940. See section 5.2.3 of SGDH
manual.

Pn202

16384

16

16384 Electronic Gear Ratio (Denominator). This parameter is not

applicable when using MP940. See section 5.2.5 of SGDH
manual.

Property

Default

Min

Max

Details (online Help message)

Advertising