13 advanced drive setup adjustments, Table 4.29 rated output operation, settings c to f, Table 4.32 high starting torque, settings 8 to b – Yaskawa AC Drive Z1000 User Manual

Page 173: Table 4.33 constant output, settings c to f

Advertising
background image

Table 4.29 Rated Output Operation, Settings C to F

Setting = C

90 Hz

Setting = D

120 Hz

Setting = E

180 Hz

Setting = F

60 Hz

0

10.4

17.3

230

1.5 3

90

60

V

oltage (V)

Frequency (Hz)

0

10.4

17.3

230

1.5 3

120

60

V

oltage (V)

Frequency (Hz)

0

10.4

17.3

230

1.5 3

180

60

V

oltage (V)

Frequency (Hz)

0

10.2

57.5

230

1.5 30

60

V

oltage (V)

Frequency (Hz)

Predefined V/f Patterns for Models 2A0024 to 2A0169 and 4A0014 to 4A0096

The values in the following graphs are specific to 200 V class drives. Double the values for 400 V class drives.

Table 4.30 Rated Torque Characteristics, Settings 0 to 3

Setting = 0

50 Hz

Setting = 1

60 Hz

Setting = 2

60 Hz

Setting = 3

72 Hz

0

8.1

230

1.3 2.5

50

16.1

V

oltage (V)

Frequency (Hz)

0

8.1

16.1

230

1.5 3

60

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

8.1

16.1

230

1.5 3

60

50

0

8.1

16.1

230

1.5 3

72

60

V

oltage (V)

Frequency (Hz)

Table 4.31 Variable Torque Characteristics, Settings 4 to 7

Setting = 4

50 Hz

Setting = 5

50 Hz

Setting = 6

60 Hz

Setting = 7

60 Hz

V

oltage (V)

Frequency (Hz)

0

6.9

230

1.3

25

50

40.3

0

8.1

230

1.3

25

50

57.5

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

6.9

230

1.5

30

60

40.3

0

8.1

230

1.5

30

60

57.5

V

oltage (V)

Frequency (Hz)

Table 4.32 High Starting Torque, Settings 8 to B

Setting = 8

50 Hz

Setting = 9

50 Hz

Setting = A

60 Hz

Setting = B

60 Hz

0

10.4

230

1.3 2.5

50

20.7

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

12.7

230

1.3 2.5

50

26.5

V

oltage (V)

Frequency (Hz)

0

10.4

230

1.5 3

60

20.7

0

15

230

1.5 3

60

26.5

V

oltage (V)

Frequency (Hz)

Table 4.33 Constant Output, Settings C to F

Setting = C

90 Hz

Setting = D

120 Hz

Setting = E

180 Hz

Setting = F

60 Hz

0

8.1

16.1

230

1.5 3

90

60

V

oltage (V)

Frequency (Hz)

0

8.1

16.1

230

1.5 3

120

60

V

oltage (V)

Frequency (Hz)

0

8.1

16.1

230

1.5 3

180

60

V

oltage (V)

Frequency (Hz)

V

oltage (V)

Frequency (Hz)

0

8.1

57.5

230

1.5 30

60

4.13 Advanced Drive Setup Adjustments

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual

173

4

Start-Up Programming & Operation

Advertising