B.1 A: Initialization Parameters

Table B.1 Symbols and Icons Used in Parameter Descriptions

Symbol

Description

Parameter can be changed during run.

OLV/PM

OLV/PM

Parameter is ONLY available when operating the drive with Open Loop Vector for PM motors.

The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, Motor

Control Method, Password, User Parameters and more.

u

A1: Initialization

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

A1-00

(100)

<1>

Language Selection

Select Language

0: English

1:

(Japanese)

3: Fran

çais

5: Español

6: Portuguêse

0: English

1: Japanese

3: French

5: Spanish

6: Portuguese

Default: 0

Range: 0 to 6

155

A1-01

(101)

<2>

Access Level Selection

Access Level

0: Operation Only

1: User Parameters

2: Advanced Level

0: View and set A1-01 and A1-04.

Uo-oo parameters can also be viewed.

1: User Parameters (access to a set of parameters selected by the

user, A2-01 to A2-32)

2: Advanced Access (access to view and set all parameters)

Default: 2

Range: 0 to 2

155

A1-02

(102)

<1>

Control Method

Selection

Control Method

0: V/F Control

5: PM OpenLoop Vect

0: V/f Control

5: Open Loop Vector Control for PM

Default: 0

Range: 0, 5

127

A1-03

(103)

Initialize Parameters

Init Parameters

0: No Initialize

1110: User Initialize

2220: 2-Wire Initial

3330: 3-Wire Initial

3410: SELVAL

HVAC Initialize

3420: SELVAL OEM

Bypass Init

0: No initialization

1110: User Initialize (parameter values must be stored using

parameter o2-03)

2220: 2-Wire Initialization

3330: 3-Wire Initialization

3410: HVAC Initialization

3420: OEM Bypass Initialization

Default: 0

Range: 0 to 3420

156

A1-04

(104)

Password

Enter Password

When the value set into A1-04 does not match the value set into

A1-05, parameters A1-01 through A1-03, A1-06, and A2-01

through A2-33 cannot be changed.

Default: 0000

Min.: 0000

Max.: 9999

A1-05

(105)

Password Setting

Select Password

When the value set into A1-04 does not match the value set into

A1-05, parameters A1-01 through A1-03, A1-06, and A2-01

through A2-33 cannot be changed.

Default: 0000

Min.: 0000

Max.: 9999

A1-06

(127)

Application Preset

Application Sel

0: General

1: Fan General

2: Fan PI

3: Fan ReturnAir/PI

4: Cooling Tower

5: CoolingTower/PI

6: Pump Secondary

7: Pump PI

0: Standard

1: Fan

2: Fan with PI Control

3: Return Fan with PI Control

4: Cooling Tower Fan

5: Cooling Tower Fan with PI Control

6: Pump (Secondary)

7: Pump with PI Control

Default: 0

Range: 0 to 7

157

<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2> Default setting value is dependent on the Application Preset selected with parameter A1-06.

B.1 A: Initialization Parameters

280

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual