B3: speed search, To restart the motor before it has completely – Yaskawa AC Drive Z1000 User Manual

Page 283

Advertising
background image

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

b2-12

(1BA)

Short Circuit Brake

Time at Start

SC Brake T@Start

OLV/PM

OLV/PM

Sets the time for Short Circuit Braking operation at start.

Default: 0.00 s

Min.: 0.00

Max.: 25.50

b2-13

(1BB)

Short Circuit Brake

Time at Stop

SC Brake T@Stop

OLV/PM

OLV/PM

Sets the Short Circuit Braking operation time at stop.

Default: 0.50 s

Min.: 0.00

Max.: 25.50

b2-18

(177)

Short Circuit Braking

Current

Shrt Cir Brk

OLV/PM

OLV/PM

Determines the current level for Short Circuit Braking. Set as a

percentage of the motor rated current.

Default: 100.0%

Min.: 0.0

Max.: 200.0

<1> Default setting is determined by parameter A1-02, Control Method Selection.

u

b3: Speed Search

No.

(Addr

Hex.)

Name

LCD Display

Description

Values

Page

b3-01

(191)

Speed Search Selection

at Start

SpdSrch at Start

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default:

<1>

Range: 0, 1

159

b3-02

(192)

Speed Search

Deactivation Current

SpdSrch DeactCur

Sets the current level at which the speed is assumed to be

detected and Speed Search is ended. Set as a percentage of the

drive rated current.

Default:

<1>

Min.: 0%

Max.: 200%

159

b3-03

(193)

Speed Search

Deceleration Time

SpdSrch Dec Time

Sets output frequency reduction time during Speed Search.

Default: 2.0 s

Min.: 0.1

Max.: 10.0

159

b3-04

(194)

V/f Gain during Speed

Search

SpdSrch V/f

Determines how much to lower the V/f ratio during Speed

Search.

Output voltage during Speed Search equals the V/f setting

multiplied by b3-04.

Default:

<2>

Min.: 10%

Max.: 100%

159

b3-05

(195)

Speed Search Delay

Time

Search Delay

When using an external contactor on the output side, b3-05

delays executing Speed Search after a momentary power loss to

allow time for the contactor to close.

Default: 0.2 s

Min.: 0.0

Max.: 100.0

b3-06

(196)

Output Current 1 during

Speed Search

Srch Im Lvl1

Sets the current injected to the motor at the beginning of Speed

Estimation Speed Search. Set as a coefficient for the motor rated

current.

Default:

<2>

Min.: 0.0

Max.: 2.0

159

b3-07

(197)

Output Current 2 during

Speed Search (Speed

Estimation Type)

Srch Im Lvl2

Sets the amount of output current during Speed Estimation

Speed Search as a coefficient for the no-load current (output

current during Speed Search is automatically limited by the

drive rated current).

Increase this setting value in increments of 0.1 if the drive fails

to perform Speed Estimation.

Default: 1.0

Min.: 0.0

Max.: 5.0

b3-08

(198)

Current Control Gain

during Speed Search

(Speed Estimation

Type)

Srch ACR P Gain

Sets the proportional gain for the current controller during

Speed Search.

Default:

<1> <2>

Min.: 0.00

Max.: 6.00

b3-09

(199)

Current Control Integral

Time during Speed

Search (Speed

Estimation Type)

Srch ACR I Time

Sets the Integral Time for the current controller during Speed

Search.

Default:

<1>

Min.: 0.0 ms

Max.: 1000.0 ms

b3-10

(19A)

Speed Search Detection

Compensation Gain

Srch Detect Comp

Sets the gain which is applied to the speed detected by Speed

Estimation Speed Search before the motor is reaccelerated.

Increase this setting if ov occurs when performing Speed Search

after a relatively long period of baseblock.

Default: 1.05

Min.: 1.00

Max.: 1.20

160

b3-11

(19B)

Speed Search Method

Switching Level (Speed

Estimation Type)

Srch Mthd Sw Lvl

Uses the amount of voltage remaining in the motor to

automatically switch the search method within the type of speed

measurement.

(200 V class at 100% = 200 V;

400 V class at 100% = 400 V)

Default: 5.0%

Min.: 0.5

Max.: 100.0

b3-12

(19C)

Minimum Current

Detection Level during

Speed Search

Srch I Deadband

Sets the minimum current detection level during Speed Search.

Increase this setting value in increments of 0.1 if the drive fails

to perform Speed Estimation.

Default:

<2>

Min.: 2.0

Max.: 10.0

B.2 b: Application

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual

283

B

Parameter List

Advertising