2 mechanical installation, Installation environment, Transporting the drive – Yaskawa AC Drive Z1000 User Manual

Page 42: Mechanical installation

Advertising
background image

2.2 Mechanical Installation

This section outlines specifications, procedures, and the environment for proper mechanical installation of the drive.

u

Installation Environment

Install the drive in an environment matching the conditions below to prolong the optimum performance life of the drive.

Table 2.1 Installation Environment

Environment

Conditions

Installation Area

Indoors

Ambient

Temperature

-10 °C to +40 °C (14 to 104 °F) IP20/NEMA Type 1 Enclosure, External Heatsink (2A0011 to 2A0273 and 4A0005 to 4A0302)

-10 °C to +50 °C (14 to 122 °F) IP00/Open Type Enclosure (2A0343 and 2A0396, and 4A0361 to 4A0590)

Note:

1. To install a heatsink on the outside of a panel, design the panel to keep the air temperature inside the panel

within 10 °C (18 °F) [5 °C (9 °F) for 2A0273 and 4A0124] of the outside air temperature.

2. Ambient temperature range for continuous operations is -10 to +40 °C (14 to 104 °F) when external heatsink

installation method is applied for models 2A0343 and 2A0396 and 4A0361 to 4A0590.

Humidity

95% RH or less and free of condensation

Storage

Temperature

-20 to +70 °C (-4 to +158 °F)

Surrounding Area

Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water, or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight.

Altitude

Up to 1000 meters without derating. Up to 3000 meters with output current and voltage derating

Vibration

10 to 20 Hz at 9.8 m/s

2

20 to 55 Hz at 5.9 m/s

2

(2A0011 to 2A0031 and 4A0005 to 4A0027) or

2.0 m/s

2

(2A0046 to 2A00396 and 4A0034 to 4A0590)

Orientation

Install the drive vertically to maintain maximum cooling effects.

NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as the noise created can lead to erroneous

operation. If such devices must be used in close proximity to the drive, take proper steps to shield the drive from noise.

NOTICE: Prevent foreign matter such as metal shavings and wire clippings from falling into the drive during installation. Failure to comply

could result in damage to the drive. Place a temporary cover over the top of the drive during installation. Remove the temporary cover before

drive start-up, as the cover will reduce ventilation and cause the drive to overheat.

u

Transporting the Drive

CAUTION! Do not lift drive models 2A0011 to 2A0114 and 4A0005 to 4A0096 by the front cover. Failure to comply might result in minor or

moderate injury if the main body of the drive falls.

Figure 2.1 Incorrect Way to Transport the Drive

2.2 Mechanical Installation

42

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual

Advertising