8 main circuit wiring, Factory recommended branch circuit protection, Main circuit terminal functions – Yaskawa AC Drive Z1000 User Manual

Page 81: Main circuit wiring

Advertising
background image

3.8 Main Circuit Wiring

This section describes the functions, specifications, and procedures required to safely and properly wire the main circuit in

the drive.

NOTICE: Do not solder the ends of wire connections to the drive. Soldered wiring connections can loosen over time. Improper wiring practices

could result in drive malfunction due to loose terminal connections.

NOTICE: Do not switch the drive input to start or stop the motor. Frequently switching the drive on and off shortens the life of the DC bus

charge circuit and the DC bus capacitors, and can cause premature drive failures. For the full performance life, refrain from switching the

drive on and off more than once every 30 minutes.

u

Factory Recommended Branch Circuit Protection

WARNING! Fire Hazard. Install adequate branch circuit protection according to applicable local codes and this manual. Failure to comply

could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more

than 100,000 RMS symmetrical amperes, 240 Vac (200 V class) and 480 Vac (400 V class), when protected by branch circuit protection

devices specified in this manual.

Branch circuit protection shall be provided by any of the following: Non-time delay Class J, T, or CC fuses sized at 300% of the drive input

rating, or Time delay Class J, T, or CC fuses sized at 175% of the drive input rating, or MCCB sized at 200% maximum of the drive input

rating.

Yaskawa recommends installing branch circuit protection according to maintain compliance with UL508C. Semiconductor

protective type fuses are preferred. Alternate branch circuit protection devices are also listed in this manual.

Refer to Factory

Recommended Z1000 AC Drive Branch Circuit Protection on page 254

for details.

u

Main Circuit Terminal Functions

Table 3.1 Main Circuit Terminal Functions

Terminal

Type

Function

Page

200 V

Class

Drive

Model

2A0011 to 2A0273

2A0343 and 2A0396

400 V

Class

4A0005 to 4A0302

4A0361 to 4A0590

R/L1

Main circuit power supply input

Connects line power to the drive

63

S/L2

T/L3
U/T1

Drive output

Connects to the motor

63

V/T2

W/T3

+1

DC power supply input (+1 and –) or

12/18 pulse rectification

For connecting peripheral devices

+3

<1>

+M

12/18 pulse rectification

<2>

Input for 12/18 pulse rectification

-M

For 200 V class: 100 Ω or less

For 400 V class: 10 Ω or less

Grounding terminal

87

<1> Not used.
<2> +M and –M are for rectification purposes only. Do not use for dynamic braking or line-regeneration.

3.8 Main Circuit Wiring

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual

81

3

Electrical Installation

Advertising