b8: Energy Saving

No.

(Addr.

Hex)

Name

LCD Display

Description

Values

Page

b8-01

(1CC)

Energy Saving Control

Selection

Energy Save Sel

0: Disabled

1: Enabled

0: Disabled

1: Enabled

Default:

<1>

Range: 0, 1

b8-04

(1CF)

Energy Saving

Coefficient Value

Energy Save COEF

Determines the level of maximum motor efficiency. Setting

range is 0.0 to 2000.0 for drives 3.7 kW and smaller.

Default:

<2> <3>

Min.: 0.00

Max.: 655.00

b8-05

(1D0)

Power Detection Filter

Time

kW Filter Time

Sets a time constant filter for output power detection.

Default: 20 ms

Min.: 0

Max.: 2000

b8-06

(1D1)

Search Operation

Voltage Limit

Search V Limit

Sets the limit for the voltage search operation as a percentage

of the motor rated voltage.

Default: 0%

Min.: 0

Max.: 100

<1> Default setting is determined by parameter A1-02, Control Method Selection.
<2> Default setting is determined by parameters A1-02, Control Method Selection, and o2-04, Drive Model Selection.
<3> Parameter value changes automatically if E2-11 is manually changed or changed by Auto-Tuning.