Terminal configuration, Wire size and torque specifications – Yaskawa AC Drive Z1000 User Manual

Page 93

Advertising
background image

u

Terminal Configuration

The control circuit terminals are arranged as shown in

Figure 3.38

.

TB3

TB1

TB2

TB4

+V AC A1 A2 FM AM AC

S1 S2 S3 S4 S5 S6 S7 SN SC SP +P FE

IG R+ R- S+ S-

M3 M4 M5 M6

MA MBMC M1 M2

Figure 3.38 Control Circuit Terminal Arrangement

n

Wire Size and Torque Specifications

Select appropriate wire type and gauges from

Table 3.10

. For simpler and more reliable wiring, use crimp ferrules on the wire

ends. Refer to

Table 3.11

for ferrule terminal types and sizes.

Table 3.10 Wire Gauges

Terminal

Screw

Size

Tightening

Torque

N

m

(lb. in)

Bare Wire Terminal

Ferrule-Type Terminal

Wire Type

Applicable

wire size

mm

2

(AWG)

Recomm.

wire size

mm

2

(AWG)

Applicable

wire size

mm

2

(AWG)

Recomm.

wire size

mm

2

(AWG)

S1-S7, SC, SN, SP

M3

0.5 to 0.6

(4.4 to 5.3)

Stranded wire:

0.2 to 1.0

(24 to 16)

Solid wire:

0.2 to 1.5

(24 to 16)

0.75 (18)

0.25 to 0.5

(24 to 20)

0.5 (20)

Shielded wire,

etc.

+V, A1, A2, AC
MA, MB, MC
M1-M6
FM, AM, AC
R+, R-, S+, S-, IG

3.9 Control Circuit Wiring

YASKAWA ELECTRIC TOEP C710616 45E YASKAWA AC Drive – Z1000 User Manual

93

3

Electrical Installation

Advertising