If you are entering a static multicast address, you must specify the
port when the multicast application is located as well as the ports
where the host nodes are connected. Assigning the address only
to the port where the multicast application is located will result in
the failure of the multicast packets to be properly forwarded to
the host nodes. You can specify the ports individually (e.g., 1,4,5),
as a range (e.g., 11-14) or both (e.g., 15-17,22,24).
The following prompt is displayed:
Please enter VLAN ID: [1 to 4094] -> 1
6. Enter the VLAN ID where the port is a member.
7. Repeat this procedure starting with Step 3 to enter additional static
unicast or multicast MAC addresses.