AT-S63 Management Software Menus Interface User’s Guide

Section II: Advanced Features

421

Displaying the

Display SNMPv3

Target Address

Table Menu

This section describes how to display the Display SNMPv3 Target
Address Table menu. For information about the SNMPv3 Target Address
Table parameters, see ”Creating an SNMPv3 Target Address Table Entry”
on page 379.

To display the Display SNMPv3 Target Address Table menu, perform the
following procedure.

1. Follow steps 1 through 5 in the procedure described in ”Displaying

the Display SNMPv3 User Table Menu” on page 416. Or, from the Main
Menu type 5->1->1->8->6.

2. From the Display SNMPv3 Table menu, type 6 to select Display

SNMPv3 Target Address Table.

The Display SNMPv3 Target Address Table menu is shown in
Figure 127.

Figure 129. Display SNMPv3 Target Address Table Menu

Displaying the

Display SNMPv3

Target

Parameters

Table Menu

This section describes how to display the Display SNMPv3 Target
Parameters Table menu. For information about the SNMPv3 Target
Parameters Table parameters, see ”Creating an SNMPv3 Target
Parameters Table Entry” on page 393.

To display the Display SNMPv3 Target Parameters Table menu, perform
the following procedure.

1. Follow steps 1 through 5 in the procedure described in ”Displaying

the Display SNMPv3 User Table Menu” on page 416. Or, from the Main
Menu type 5->1->1->8->6.

2. From the Display SNMPv3 Table menu, type 7 to select Display

SNMPv3 Target Parameters Table.

Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63

Marketing

User: Manager

11:20:02 02-Oct-2004

Display SNMPv3 Target Address Table

Target Addr Name ... host99

Timeout ..... 1500

Target Parameters .. SNMPmanagerPC

Retries ..... 5

IP Address ......... 198.35.11.1

UDP Port# ... 162

Storage Type ....... NonVolatile

Row Status .. Active

Tag List ........... engTrap engInform

U - Update Display
R - Return to Previous Menu

Enter your selection?