Chapter 29: 802.1x Port-based Network Access Control

636

Section IV: Security

Configuring Supplicant Port Parameters

To configure supplicant port parameters, perform the following
procedure:

1. From the Main Menu, type 8 to select Security Configuration.

The Security Configuration menu is shown in Figure 175 on page
559.

2. From the Security Configuration menu, type 1 to select Port Access

Control (802.1X).

The Port Access Control (802.1X) menu is shown in Figure 197 on
page 629.

3. From the Port Access Control menu, type 5 to select Configure

Supplicant.

The Configure Supplicant menu is shown in Figure 199.

Figure 201. Configure Supplicant Menu

4. From the Configure Supplicant menu, type 1 to select Configure

Authenticator Port Access Parameters.

The following prompt is displayed:

Enter port list ->

5. Enter the supplicant port number whose parameters you want to

change. You can specify one port or a range of ports (for example, 4-
8), but not multiple individual ports (for example, 4,6,11).

Note

A port must already be configured as an supplicant before you can
configure its settings. For instructions on how to change the role of
a port, refer to ”Setting Port Roles” on page 629.

Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63

Marketing

User: Manager

11:20:02 02-Oct-2004

Configure Supplicant

1 - Configure Supplicant Port Access Parameters
2 - Display Supplicant Port Access Parameters

R - Return to Previous Menu

Enter your selection?