The Configure Supplicant Port Access Parameters menu is shown
in Figure 200.

Figure 202. Configure Supplicant Port Access Parameters Menu

6. Adjust the following parameters as necessary.

1 - Auth Period
This parameter specifies the period of time in seconds that the
supplicant waits for a reply from the authenticator after sending
an EAP-Response frame. The range is 1 to 60 seconds. The default
is 30 seconds.

2 - Held Period
The held period specifies the amount of time in seconds the
supplicant is to refrain from retrying to re-contact the
authenticator in the event the end user provides an invalid
username and/or password. After the time period has expired, the
supplicant can attempt to log on again. The range is 0 to 65,535.
The default value is 60.

3 - Max Start
Max start is the maximum number of times the supplicant sends
EAPOL-Start frames before assuming that there is no
authenticator present. The range is 1 to 10. The default is 3.

4 - Start Period
The start period is the time period in seconds between successive
attempts by the supplicant to establish contact with an
authenticator when there is no reply. The range is 1 to 60. The
default is 30.

Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63

Marketing

User: Manager

11:20:02 02-Oct-2004

Configure Supplicant Port Access Parameters

Configuring Port 5-8

1 - Auth Period........... 30 Seconds
2 - Held Period........... 60 Seconds
3 - Max Start ........... 3
4 - Start Period.......... 30 Seconds
5 - User Name: ...........
6 - User Password: .......

R - Return to Previous Menu

Enter your selection?