Chapter 3: Basic Switch Parameters

76

Section I: Basic Features

Displaying Uplink Port Information

To display the information about the GBIC or SFP transceivers installed in
the uplink ports, perform the following procedure:

1. From the Main Menu, type 5 to select System Administration.

The System Administration menu is shown in Figure 4 on page 51.

2. From the System Administration menu, type 1 to select System

Information

The System Information menu is shown in Figure 6 on page 56.

3. From the System Information menu, type U to select Uplink

Information.

The Uplink Information menu is shown in Figure 14.

Figure 14. Uplink Information Menu

The Uplink Information menu displays the status of the GBIC/SFP
uplink ports, ports 23 and 24. If a GBIC or an SFP transceiver is
installed in one of the slots, the display shows “Present.” “Not
Present” indicates that no GBIC or SFP transceiver is installed in
that slot.

Note

The Uplink Information menu only indicates that a GBIC or an SFP is
inserted in the slot. It does not indicate whether or not a fiber optic
cable is connected to the GBIC or SFP.

4. Type the number corresponding to the slot where the transceiver is

identified as “Present” to view detailed information about that
transceiver. The information displayed depends upon the transceiver
vendor and whether the slot contains an SFP or a GBIC transceiver.

Allied Telesyn Ethernet Switch AT-9400 Series - AT-S63

Marketing

User: Manager

11:20:02 02-Oct-2004

Uplink Information

1 - GBIC/SFP 1 ............ Not Present
2 - GBIC/SFP 2 ............ Present

R - Return to Previous Menu

Enter your selection?