Publication 1398-5.2 – PDF 1997

6-38

Interfaces

Multiple Axes RS-232 Communications

Multiple axes systems may be controlled by a computer with an RS-
232 serial port. An RS-232 serial communication port may be
converted to four wire RS-485 communication by attaching an RS-
232 to four-wire RS-485 converter. The figure below depicts the use
of such a device.

Figure 6.42

RS-232 to RS-485 Connection Diagram

PC

* Pin-outs may
vary by manufacturer.

This example uses a

Drive 1

RCV+

RCV-

XMT+

J5

1

7

4

8

XMT-

COM
RCV-
RCV+
XMT-
XMT+

Drive 2

RCV+

RCV-

XMT+

J5

1

7

4

8

XMT-

Drive n

RCV+

RCV-

XMT+

J5

1

7

4

8

XMT-

232 to 485

Adapter

.......

7*
5*
17*
3*
14*

3*

2*

7*

COM*

RCV*

XMT*

RS-232

Interface

+

12 V

D

C

Re

tu

rn

B&B 485 Adapter

Advertising