Cabling examples, Motor – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 226

Advertising
background image

Publication 1398-5.2 – PDF 1997

B-24

Cable Diagrams, Schematics and Examples

BCable Diagrams, Schematics and Examples

Cabling Examples

Figure B.24

F- or H-Series Motors to ULTRA 100 Series Drive

Intro

Motor Power Cable

Clamp exposed
to the chassis

Motor

Motor Power Connector

Encoder Connector

P2

9101-1366-XXX

ground terminal

motor cable shield

Screw Terminal Strip

Enclosure/Cabinet

P1

9101-1391

To

Control

Interface

NOTES:

This wiring method should be used to run cables through a bulkhead or enclosure without
removing the connectors.

Cable 9101-1366-XXX has connectors on both ends. The connectors are molded and potted to
the cable and may not be disassembled.

Adaptor Kit 9101-1391 includes the 3 foot cable, screw terminal strip and mounting bracket. The
cable has a 50-pin Mini D ribbon connector at the drive end and a 50-pin D connector at the ter-
minal strip end.

Motor Power Cables - Use ULTRA 100 Series cables if the CE Mark is required. Other cables
may be used if the CE Mark is not an issue. In either case, the shield on the motor power cable
must be properly grounded at both ends; the shield is grounded at the motor end when the MS
connector is mated.