Application and Configuration Examples

8-7

3. Connect a Power cable from the motor to TB1 (terminals R, S, T

and

) on the drive.

4. Connect a jumper wire with a toggle switch between the following

pins:

• J1-20 (ENABLE) and J1-26 (I/O PWR)

• J1-32 (INPUT1) and J1-26 (I/O PWR)

• J1-33 (INPUT2) and J1-26 (I/O PWR)

• J1-34 (INPUT3) and J1-26 (I/O PWR)

• Connect a switch between J1-21 (FAULT RESET) and J1-26

(I/O PWR).

These connections provide manual control for enabling or disabling
the drive and resetting faults. The figure below shows the jumper,
including normally open toggle switches.

1. Connect an external 12 to 24 VDC power source for powering I/O

to J1-5 (I/O PWR) and J1-6 (I/O COM).

2. Connect the drive to a single phase 100-240 VAC, 50/60 Hz power

source.

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

Figure 8.2

Preset Controller Connection Diagram

J1

26 I/O PWR

20 ENABLE

21 FAULT

32 INPUT1

33 INPUT2

Close to ENABLE Drive

Close to RESET Fault

34 INPUT3

Close to Turn ON

Close to Turn ON

Close to Turn ON

DRIVE

L1 3

L2/N 4

Gnd 5

100-240 VAC

50/50 Hz

Single Phase

Power Source

J5

2 RCV

3 XMT

5 COM

XMT

RCV

COM

RESET

TB1

Phase R 6

Phase S 7

Phase T 8

Mtr Gnd 9

J2

Motor

Encoder

External I/O

12-24 VDC

Power Source

5 I/O PWR

6 I/O COM