3-4

Selecting Other System Components

Host computers

Programmable Logic Controllers

Motion controllers

TouchPad.

The serial communication interface for the ULTRA 100 Series
supports:

RS-232 and the four wire RS-485 communications standards

NRZ (non-return to zero) asynchronous serial format

Baud rates: 1200, 2400, 4800, 9600 and 19200

Parity generation and checking: Even, Odd or None.

Connection of communication cables between the drive and user-
supplied equipment is described in the following sections:

One ULTRA 100 Series drive - “Single Axis RS-232 Set Up” on
page 6-34

Multiple ULTRA 100 Series drives - “Multiple Axes Four-wire
RS-485 Communications” on page 6-35
.

Analog Command Sources

In the analog mode of operation, the ULTRA 100 Series drive requires
a variable ±10 Volt DC external analog signal capable of driving the
servo regulator’s command input at an input impedance of
13.3 kOhms. Choose a source such as a PLC (programmable logic
controller), the DAC (digital-to-analog converter) of a computer, or a
motion controller that meets this requirement.

Differential or single-ended line drivers may supply the signals for the
auxiliary encoder inputs, step and direction inputs, and step up/down
inputs. The differential signal must be capable of supplying at least 5
mA with 2.0 Volts across the + and - inputs. A differential signal
source provides the best noise margin of all the interface circuit
options. Single-ended signals from TTL drivers must be capable of
sourcing or sinking 5 mA.

In preset mode, the controlling device should be able to source 10 mA
into the digital inputs.

I/O Interface

Analog Input

One analog input channel is accessible to the user. The analog input
limits the peak current available from the drive.

I LIMIT (current limit)

The analog signal must be within 0-10 Volt range and single-ended.

Advertising