Connection diagram, Configuration, Position follower (step up/down controller) – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 139: Connection diagram configuration

Advertising
background image

Publication 1398-5.2 – PDF 1997

Application and Configuration Examples

8-25

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• Status LED is green. Refer to “Status Indicator” on page 10-1

for an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

5. Verify the communications port settings of the PC match those of

the drive.

• If the settings are correct, select

OK

in the Port - Settings dia-

log box.

Figure 8.5

Position Follower (Step Up/Down Controller)
Connection Diagram

J1

14 CW+

15 CW-

16 CCW+

Close to ENABLE Drive

Close to RESET Fault

17 CCW-

Close to Follow

21 FAULT

26 I/O PWR

32 INPUT1

20 ENABLE

Step

Indexer

Note: Refer to Figure 6.34 and 6.35 for additional details
on the Control Interface Cable.

DRIVE

L1 3

L2/N 4

Gnd 5

100-240 VAC

50/50 Hz

Single Phase

Power Source

RESET

TB1

Phase R 6

Phase S 7

Phase T 8

Mtr Gnd 9

J2

Motor

Encoder

External I/O

12-24 VDC

Power Source

5 I/O PWR

6 I/O COM

J5

2 RCV

3 XMT

5 COM

XMT

RCV

COM