Interfaces

6-3

Digital Inputs

ULTRA 100 Series drives have active high inputs, which prevent
disconnects and ground faults from activating a drive. The typical ON
time for an input to be recognized is 2.0 msec.

Two discrete input circuits types are available on the J1 connector.
Both circuits support logic type interfaces with optically isolated,
single ended and active high characteristics.

Dedicated Control Circuits

The ENABLE input interface with switch closures or sourcing type
outputs.

Selectable Circuits

INPUT 1, INPUT 2, INPUT 3 and FAULT RESET operate with
switch closures or sourcing type circuitry. Selectable inputs are:

13 I/O COM

External I/O
Common

32 INPUT1

Selectable
Input 1

14 AX+/

CW+/
STEP+

Auxiliary
Encoder Chan-
nel A+

33 INPUT2

Selectable
Input 2

15 AX-/CW-/

STEP-

Auxiliary
Encoder Chan-
nel A-

34 INPUT3

Selectable
Input 3

16 BX+/

CCW+/
DIR+

Auxiliary
Encoder Chan-
nel B+

35

Reserved

17 BX-/

CCW-/
DIR-

Auxiliary
Encoder Chan-
nel B-

36

Reserved

18 IX+

Auxiliary
Encoder Chan-
nel I+

37

Reserved

19 IX-

Auxiliary
Encoder Chan-
nel I-

38

Reserved

Table 6.1:

J1 Controller Pin-Outs

(continued)

Pin & Signal

Description

Pin & Signal

Description

Pin & Signal

Description

pin 25

pin 26

pin 50

pin 1

Figure 6.1

Digital Input Circuit

Drive

J1

3K

1K

I/O COM