Selecting Other System Components

3-3

One dedicated, control (ENABLE), optically isolated, active high
input.

Two selectable, optically isolated and short circuit protected,
active high outputs.

Two dedicated (BRAKE/DRIVE ENABLED and DRIVE
READY), normally open relay outputs.

Analog I/O

A dedicated analog input provides current limiting capabilities, while
the analog output can be customized to fit the application:

One dedicated 0 - 10 Volt, analog input (EXTERNAL CURRENT
LIMIT)

One selectable, ±10 Volt analog output.

AC Input Power

ULTRA 100 Series drives covered by this manual are powered
directly from a main 100-240 VAC single phase line.

Personality Module

EEPROM (electrically erasable programmable read only memory)
stores both motor and application specific settings and parameters for
the drive.

Multiple Protection Circuits

Device and circuit protection, and diagnostic information is provided
by:

Bi-color single point LED

Overtemperature, short circuit and overcurrent protection for the
power output

I

2

T (power-time) protection for the motor and the power drive

Bus Overvoltage

Bus Undervoltage

Overspeed

Fault diagnostics

Watchdog timers provide fail-safe operation.

Command Sources

Serial Command Sources

ULTRA 100 Series drives are configured and controlled via a serial
communication link. Commands may be issued from a variety of
sources through a serial communications port. Possible command
sources include:

Personal computers