Analog outputs: analog 1, Analog output specifications – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 80

Advertising
background image

Publication 1398-5.2 – PDF 1997

6-16

Interfaces

A selectable output is available for monitoring by the user: ANALOG
1 (J1-31).

The following signals can be mapped to the analog output.

The following signals can also be monitored when ULTRA Master is
configured for Advanced Mode.

!

Intro

ATTENTION: The user must provide an external circuit
to ignore the analog output signal for two seconds after
power-up. After reset the analog output may be in an inde-
terminate state for a short period before it stabilizes at the
software controlled setting. Failure to observe this precau-
tion could result in severe bodily injury.

Table 6.15:

Analog Outputs: ANALOG 1

Analog
Output

Pin Number

Description

ANALOG 1

J1-31

Selectable analog output. Displays the selected firm-
ware variable along with selectable scale and offset.
The scale or offset are calculated as shown below.

ACOM

J1-28

Analog Common (return).

Table 6.16:

Analog Output Specifications

Parameter

Description

Minimum

Maximum

Output Current

Allowable current draw of the load

-2 mA

+2 mA

Output Signal
Range

Voltage range of the signal

-10 Volts

+10 Volts

Current – Command

Velocity – Command

Current – Average

Velocity – Error

Current – Peak +

Position – Motor Feedback

Current – Peak -

Position – Command

Current – Input Limit +

Position – Error

Current – Input Limit -

Position – Error Peak +

Velocity – Motor Feedback

Position – Error Peak -

Position – Master

Torque Current

Position – Loop Output

Field Current

Velocity – Loop Output

Torque Voltage Command

Advertising