Application and Configuration Examples

8-19

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• Status LED is green. Refer to “Status Indicator” on page 10-1

for an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

5. Verify the communications port settings of the PC match those of

the drive.

• If the settings are correct, select

OK

in the Port - Settings dia-

log box.

Figure 8.4

Position Follower (Step/Direction) Connection Diagram

J1

Close to ENABLE Drive

Close to RESET Fault

Close to Follow

20 ENABLE

21 FAULT

26 I/O PWR

32 INPUT1

Note: Refer to Figure 6.25, 6.26, 6.27, 6.28, 6.29, 6.30 and
6.31 for additional details on the Control Interface Cable.

J5

DRIVE

2 RCV

3 XMT

5 COM

L1 3

L2/N 4

Gnd 5

XMT

RCV

COM

100-240 VAC

50/60 Hz

Single Phase

Power Source

RESET

TB1

Phase R 6

Phase S 7

Phase T 8

Mtr Gnd 9

J2

Motor

Encoder

5 I/O PWR

6 I/O COM

Step/Dir

Generator

14 AX+

STEP+

15 AX–

STEP–

16 BX+

DIR+

17 BX–

DIR–

External I/O

12-24 VDC

Power Source