Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 288

Advertising
background image

Publication 1398-5.2 – PDF 1997

G-2

Specifications

Digital Outputs

Selectable (2)

12-24 Volt, Short Circuit Protected, Optically Isolated, Sin-
gle-ended, Active High, 50 mA maximum

BRAKE

Normally Open Relay, 1 A

READY

Normally Open Relay, 100 mA

Digital I/O Power Supply

User supplied 12 to 24 VDC

Analog Inputs

Current Limit
(I LIMIT)

0 to 10 Volt, single-ended, 5 kOhm input Impedance

COMMAND

±10 Volt, Differential, 13 kOhm input Impedance, offset soft-
ware adjustable

Analog Outputs

ANALOG1

0 to 10 Volt, 8 bits, 2 mA maximum

Auxiliary Encoder Input

Auxiliary Encoder Signal Input

26LS33 Input, 4 MHz Count Frequency

Differential/Single-ended

A/B

Step/Direction

CW/CCW

Motor Encoder Output

Motor Encoder Output

AM26C31 or AM26LS31 Differential Driver, Divide by 1, 2, 4,
or 8

Differential output is 2.0 Vdc across a 100 Ohm load

Memory

Parameter Data Retention

20 years

Motor Protection

Motor Overload Protection

The drive utilizes solid state motor overload protection which
operates:

• within 8 minutes at 200% overload

• within 20 seconds at 600% overload

Speed Regulation

Type

Digital, PI

-3dB Bandwidth

300 Hz

-45° Bandwidth

50 Hz

Ripple

±0.44 rpm with 5000 line encoder

Speed Range

1:8000 rpm

Position Regulation

Type

Digital, PI with Feedforward

Filters

Low Pass

Digital, 0 - 1000 Hz, -3 dB Bandwidth, Selectable