10-2

Status Display

Power-Up Error Codes

A power-up error indicates in almost all cases that the drive should be
returned to the factory for service. In general, any occurrence of a
Power-up error should be treated with extreme caution. It may
indicate the hardware is marginal.

Situations that may cause drive hardware errors, and which can be
remedied outside the factory include:

A watchdog time-out error may result from electrical “noise”
(electromagnetic interference - EMI), a firmware error, or a hardware
malfunction. The context of the watchdog error needs to be
investigated to determine the source of the problem.

Table 10.2 lists the Power-Up Error Codes.

21

Auxiliary Encoder State Error

22

Motor Thermal Protection

23

IPM Thermal Protection

24

Excess Velocity Error

25

Commutation Angle Error

26 Reserved

27

Axis not Homed

28

No Motor Selected

29

Motor Selection not in Table

30

EEPROM Write Error

31 - 50

Reserved

Table 10.1:

List of Run Time Error Codes

(continued)

Error Code

Fault Description

Table 10.2:

List of Power-Up Error Codes

Error Code

Fault Description

51

Program Memory Boot Block Error

52

Program Memory Main Block Error

53

Uninitialized Personality EEPROM Error

54

Personality EEPROM Read Error

55

Personality EEPROM Data Corruption

56

Processor Watchdog Error

57

Reserved

58

Processor RAM Error

59

Reserved

60

Uninitialized Service EEPROM Error

61

Service EEPROM Read Error

62

Service EEPROM Data Corruption Error

63 - 73

Reserved

74

Personality EEPROM Write Error

75 - 78

Reserved