Publication 1398-5.2 – PDF 1997

Application and Configuration Examples

8-33

9. If the message box appears that a motor must be selected, select

OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

.

12. Select

Inde

x

ing

as the Operation Mode for the drive.

13. Choose

Close

to exit the Drive Set Up window.

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Indexing tab

.

15. Enter the following values for Index 0. Refer to “Incremental

Indexing Examples” on page 8-30 for examples of Single and
Batched Incremental Indexing profiles.

16. Choose

Close

to exit the Drive Parameters window.

17. Verify the Status indicator is green.

18. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

19. Select an appropriate digital input from the pull-down lists avail-

able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:

Start Index

as Input 1

Not Assigned

as Inputs 2 through 3.

Single Move Settings

Batched Move Settings

Incremental

as Mode

Incremental

as Mode

8000

as Distance

8000

as Distance

1

as the Batch Count

3

as the Batch Count

0

as Dwell

1000

as Dwell

Appropriate values for
Acceleration and Decelera-
tion

Appropriate values for
Acceleration and Decelera-
tion