Single Axis RS-232 Set Up

A single ULTRA 100 Series drive may be selected using RS-232
communications. After cabling is attached to the unit and the drive
address is assigned, configuration of (i.e., communications with) the
unit may proceed.

Factory default settings for a ULTRA 100 Series drive are:

Address 0

9600 Baud

8 Data, No Parity, 1 Stop bit

The following steps outline how to select the communications options:

1. Connect an RS-232 cable between the computer and a serial con-

nector on the drive (J5).

2. Verify the computer can communicate with the drive by perform-

ing the following:

A. Switch drive power to ON

B. Start ULTRA Master on the attached PC

C. Choose

CANCEL

from the Drive Select window

Figure 6.40

RS-232 Connection Diagrams

USER

2

9-Pin

Drive

2

Drive Chassis

PC

3

3

5

Male

RS-232 CABLE

J5

2

3

5

RCV

XMT

COM

RCV*

XMT*

COM*

* PC pin-outs

may vary by

manufacturer

9-Pin
Female

9-Pin Male Connector to 9-Pin Female Connector

9-Pin
RS-232

USER

2

9-Pin

Drive

2

Drive Chassis

PC

3

3

5

7

Male

RS-232 CABLE

J5

2

3

5

RCV

XMT

COM

XMT*

RCV*

COM*

25-Pin
Female

9-Pin Male Connector to 25-Pin Female Connector

25-Pin
RS-232

5

* PC pin-outs

may vary by

manufacturer