Publication 1398-5.2 – PDF 1997

8-46

Application and Configuration Examples

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to “RS-232 Communication Test” on page 11-8 for
troubleshooting instructions.

6. Select

Read Drive

P

arameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that is

being addressed.

8. Choose

OK

to load the drive parameters.

9. If the message box appears that a motor must be selected, select

OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

.

12. Select

Inde

x

ing

as the Operation Mode for the drive.

13. Choose

Close

to exit the Drive Set Up window.

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Indexing

tab.

15. Select the following values for Index 0:

16. Choose

Close

to exit the Drive Parameters window.

17. Verify the Status indicator is green.

18. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

Note: A motor must be selected for the parameters to load.

Absolute

as Mode

8000

as Position

1

as Batch Count

0

as Dwell

Appropriate values for
Velocity, Acceleration and
Deceleration