Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 252

Advertising
background image

Publication 1398-5.2 – PDF 1997

C-20

TouchPad Instructions

5v Fuse

+5 VDC Fuse blown

not applicable to 1398-DDM-005, 1398-DDM-005X, 1398-DDM-009, 1398-DDM-009X, 1398-DDM-019
or 1398-DDM-019X

EncFuse

Encoder Power Fuse blown

not applicable to 1398-DDM-005, 1398-DDM-005X, 1398-DDM-009, 1398-DDM-009X, 1398-DDM-019
or 1398-DDM-019X

MtrOvT

Motor Thermostat Overtemperature

IPMFalt

IPM Fault (Overtemperature/Overcurrent/Short Circuit)

IMLinBk

Channel IM Line Break

BMLinBk

Channel BM Line Break

AMLinBk

Channel AM Line Break

BusOvV

Bus Undervoltage

BusUndV

Bus Overvoltage

IlglHal

Illegal Hall State

SubIntr

Unused Interrupt - sub processor

MainInt

Unused Interrupt - main processor

ExsAvgI

Excessive Average Current

OvSpeed

Motor Overspeed

ExsFErr

Excessive Following Error

MtrEnc

Motor Encoder State Error

MstrEnc

Auxiliary Encoder State Error

MtrThrm

Motor Thermal Protection

IPMThrm

IPM Thermal Protection

EnNoMtr

No Motor Selected while enabling drive

MtrType

Motor Selection not in Table

PersWrt

Personality Write Error

ServWrt

Service Write Error

CPU-
Comm

CPU Communications Error

MtrOvt

Motor Overtemperature

IPMFalt

IPM Fault

ExsVErr

Excess Velocity Error

Comutat

Commutation Angle Error

Not
Homd

Axis Not Homed

NOTE:

The Drive Status display is read-only.

DrvEnab

and

DrvRdy

indicate

that the drive is functional. The other displays indicate an error condition.

Table C.17:

Drive Status List for TouchPad

(continued)

Display

Parameter

Table C.18:

Input Flags Parameter List for TouchPad

Display

Parameter

FltRst

Fault Reset Input Flag

ENABLE

Drive Enable Input Flag