Publication 1398-5.2 – PDF 1997

Application and Configuration Examples

8-3

• If the settings are correct, select

OK

in the Port - Settings dia-

log box.

• If the settings are different, correct the Port - Settings to allow

communications with the drive.

Factory default communications Port - Settings for the drive
are:

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to “RS-232 Communication Test” on page 11-8 for
troubleshooting instructions.

6. Select

R

ead Drive Parameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that is

being addressed.

8. Choose

OK

to load the drive parameters.

9. If the message box appears that a motor must be selected, select

OK

. The Drive Set Up window is displayed with Motor Model

selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

.

12. Select the Operation Mode parameters for the drive:

13. Choose

Close

to exit the Drive Set Up window.

14. Choose the

Drive

P

arameters

icon from the Drive window and

then select the

Analog

tab.

15. Enter appropriate S

cale

and O

ffset

values for the input.

16. Verify the Status indicator is green.

Note: A motor must be selected for the parameters to load.

Velocity Mode Settings

Torque Mode Settings

A

nalog Velocity Input

as the Operation Mode

Analog Torque

I

nput

as

the Operation Mode