Interfaces, J1 – controller, Digital i/o power – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 65: External i/o power, Chapter 6, E 6-1

Advertising
background image

Publication 1398-5.2 – PDF 1997

Chapter 6

Interfaces

Chapter 6

This chapter provides information about:

Interface signals available on the ULTRA 100 Series drive

• J1 - The Controller interface for commanding and reporting

motion

• J2 - The Encoder interface for reporting movement by the

motor

• J5 - The Serial interface for communicating with the drive.

Commonly encountered interface cabling methods

Optional signal extension kits and standard cables.

J1 – Controller

J1 is a 50 pin female mini-D connector (AMP 2-178238-7) for
connecting a host computer or controller to the drive. Contact between
the connector’s shell and the grounded chassis provides shield
termination. This section lists the connector pin-outs and provides
signal specifications.

Cables are available in various lengths for connecting between J1 and
a suitable controller. The appendix “Options and Accessories” on
page A-1
lists the cables. “J1 Terminal Strip/Breakout Board” on
page 6-24 d
etails the optional signal extension kit that is available.
“Interface Cable Examples” beginning on page 6-21 depict various
interface cable types commonly encountered in applications.

Digital I/O Power

The drive requires an external 12 to 24VDC power source for the
inputs and outputs.

External I/O Power

The external I/O power supply must be capable of supplying at least
250 mA.

The pin-outs are:

The external I/O COM must be grounded to meet the European Low
Voltage Directive (LVD).

I/O PWR (12 to 24 Volts)

J1-5

J1-26

I/O COM

J1-6

J1-13

Advertising