Safety

All non-qualified personnel should maintain a safe distance from
the equipment.

The system must be installed in accordance with local regulations.

The equipment is intended for permanent connection to a main
power input. It is not intended for use with a portable power input.

Do not power up the unit without the covers in place and the
protective conductor connected.

Do not operate the unit without connecting the motor conductor to
the appropriate terminal on the drive.

Always remove power before making or removing any connection
on the unit.

Before removing the cover of the unit, shut off the main power
and measure the DC bus voltage to verify it has reached a safe
level or wait for the time as indicated on the front of the drive.

Do not make any connections to the internal circuitry.
Connections on the front panel are the only points where users
should make connections.

Be careful of the DC bus and shunt terminals. High voltage is
present when power is applied to the drive.

Never connect the DC- (negative) terminal to earth ground, the
drive requires a floating DC bus.

Do not use the ENABLE input as a safety shutdown. Always
remove power to a drive before maintaining or repairing the unit.

Motors without thermal protection devices require a valid thermal
time constant. Otherwise the motor overload protection will not
function properly.