Position follower (step up/ down), Hardware set up, Position follower (step up/down) – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 138

Advertising
background image

Publication 1398-5.2 – PDF 1997

8Application and Configuration Examples

Position Follower (Step Up/
Down)

The ULTRA 100 Series can be set up as a Position Following using
Step Up and Step Down signals typically used to control stepper
drives. The connection diagram depicts the minimum hardware
necessary. Interfacing the drive to a controller requires similar
circuitry from the indexer to J1. Instructions are provided to configure
the drive with ULTRA Master software.

Hardware Set Up

Make the connections described below and shown in the Figure 8.5.
The appendix “Options and Accessories” on page A-1 lists the
interconnect cables available from the factory.

1. Connect an RS-232 cable between the serial port on the PC and

the J4 connector on the ULTRA 100 Series. A simple 3 wire cable
is depicted in the figure below.

2. Connect a Motor/Feedback cable from the motor to the J2 connec-

tor on the ULTRA 100 Series.

3. Connect a Power cable from the motor to TB1 (terminals R, S, T

and

) on the drive.

4. Connect the Stepper Indexer to the drive as shown in the diagram.

5. Connect a jumper wire with a toggle switch between the following

pins:

• J1-20 (ENABLE) and J1-26 (I/O PWR)

• J1-32 (INPUT1) and J1-26 (I/O PWR)

• J1-21 (FAULT RESET) and J1-26 (I/O PWR).

These connections provide manual control for enabling or
disabling the drive and resetting faults. The figure below shows
the jumper, including normally open toggle switches.

6. Connect an external 12 to 24 VDC power source for powering I/O

to J1-5 (I/O PWR) and J1-6 (I/O COM).

7. Connect the drive to a single phase 100-240 VAC, 50/60 Hz power

source.

Advertising