Application and Configuration Examples

8-9

12. Select the Operation Mode parameter for the drive:

13. Choose

Close

from the Drive Setup window.

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Preset

tab.

15. Enter the appropriate parameters for the Command mode in

which the drive will operate:

Up to eight presets (0-7) may be programmed.

16. Choose

Close

to exit the Drive Parameters window.

17. Verify the Status indicator is green.

18. Select the

I/O

C

onfiguration

command icon from the Drive win-

dow.

19. Assign one of the three Preset Selects (A, B and C) to each of the

Digital Input Assignments. For example, the following selects
three presets:

I

n

put 1

to

Preset Select A

In

p

ut 2

to

Preset Select B

Inp

u

t 3

to

Preset Select C

The presets provide up to eight binary combinations of speed or
current. Unassigned preset inputs should be set to

Not Assigned

,

which forces an OFF state.

20. Verify all Digital Output Assignments are

Not Assigned

.

21. Choose

Close

to exit the I/O Configuration window.

Tuning

Velocity Mode Settings

Torque Mode Settings

Preset

V

elocities

as the

Operation Mode

Preset

T

orques

as the

Operation Mode

Velocity Mode Settings

Torque Mode Settings

Enter the appropriate
velocity value for each
speed required

Enter the appropriate cur-
rent value for each torque
required

Note: Do not attempt to Tune a drive with the Command mode set for

Preset Torques

. If the drive is set to Torque mode, continue with the

Operation section below.

Do not attempt to Auto Tune systems that have gravitational effects.
The ULTRA 100 Series will not hold initial position.