Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 128

Advertising
background image

Publication 1398-5.2 – PDF 1997

8-14

Application and Configuration Examples

Factory default communications Port - Settings for the drive
are:

– Baud Rate:

9600

– Data Bits:

8

– Parity:

None

– Stop Bits:

1

– Serial Port:

COM1

Refer to “RS-232 Communication Test” on page 11-8 for
troubleshooting instructions.

6. Select

R

ead Drive Parameters

from the Communications menu.

7. Verify the Drive Name and Address are correct for the drive that is

being addressed.

8. Choose

OK

to load the drive parameters.

9. If the message box appears that a motor must be selected, select

OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.

10. Select or verify the correct motor model number from the drop

down Motor Model list.

11. If a message advises that the drive must be reset, choose

Yes

,

12. Select

Follower: Master

E

ncoder

as the Operation Mode for the

drive.

13. Choose

Close

from the Drive Setup window.

14. Choose the

Drive

P

arameter

command icon from the Drive win-

dow, and then select the

Follower

tab.

15. Enter an appropriate

G

ear Ratio

as the Follower Input. The

default Gear Ratio is 1:1 (motor encoder pulses:master pulses). If
a Gear Ratio of 3:1 is entered, the motor is moved 3 encoder
pulses for every incoming master pulse.

16. Choose

Close

to exit the Drive Parameters window.

17. Verify the Status indicator is green.

18. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

Note: A motor must be selected for the parameters to load.

Advertising