Modifying User Units

The units displayed for any ULTRA 100 Series drive may be modified
using a PC with ULTRA Master software. The PC Display Units help
menu defines the various parameters displayed by ULTRA Master.
Default settings for Units are shown in Figure 8.12.

Changing the Display Units Settings

The following example changes the Label and Conversion Factor for
the Position and Acceleration parameters. This example assumes a
2000 line encoder (8000 pulses/revolution).

Position - from Counts to Motor Revolutions

Acceleration - from RPM/sec

2

to Revs/sec

2

1. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

U

nits

button. The PC Display Units

dialog appears with default settings as shown.

2. Select the Position Label cell, and change

counts

to

Mtr Revs

.

3. Select the Position Conversion Factor cell, and change

1000

to

0.125

.

Mathematically 1/8 (0.125) of a motor revolution is 1000 counts,
given that the motor has a 2000 line (8000 count) encoder.

4. Select the Acceleration Label cell, and change

RPM/sec

to

Revs/

sec

.

5. Select the Acceleration Conversion Factor cell, and change

1.

to

.016

.

Mathematically 1.6 x 10

-2

revs/sec

2

is 1 RPM/sec, given the

motor has a 2000 line (8000 count) encoder.

Figure 8.12

PC Display Units – Default Dialog

Intro

Intro

PC Display Units

Display System Units

OK

Cancel

Help

Parameter:

Velocity

Torque

Position

Acceleration

Label:

Conversion

RPM

Amps

counts

RPM/sec.

1.

1.

1.

1000.

= 1 RPM

= 1 Amp

= 1000 counts

= 1 RPM/sec.

Unit Definitions

Factor:

Note: Labels are limited to eight characters.