Drive output connected to an opto-isolator, Drive output connected to an led indicator, Drive output connected to a resistive load – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 76: Transistor output specifications, The command input supports 0 to ±10 volt signals

Advertising
background image

Publication 1398-5.2 – PDF 1997

6-12

Interfaces

The command input supports 0 to ±10 Volt signals.

Table 6.10:

Transistor Output Specifications

Parameter

Description

Minimum

Maximum

ON state Voltage

Voltage difference between the external I/O
power supply and the output when the transis-
tor is ON

0 VDC

1.5 VDC

ON state current

Current flow when the transistor is ON

0 mA

50 mA

OFF state Voltage

Voltage difference between the external I/O
power supply and the output when the transis-
tor is OFF

0 Volts

50 Volts

OFF state current

Leakage current from the output when the
transistor is OFF

-0.1 mA

0.1 mA

Figure 6.11

Drive Output Connected to an Opto-Isolator

Figure 6.12

Drive Output Connected to an LED Indicator

Figure 6.13

Drive Output Connected to a Resistive Load

Drive

J1

I/O Pwr

Pin 13

Pin 6

I/O COM

1K

1K

I/O Pwr

Pin 13

Pin 6

Drive

J1

I/O COM

Pin 13

Pin 6

Drive

J1

I/O COM

I/O Pwr

1K

Advertising