Drive output connected to an opto-isolator, Drive output connected to an led indicator, Drive output connected to a resistive load – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual
Page 76: Transistor output specifications, The command input supports 0 to ±10 volt signals
Publication 1398-5.2 – PDF 1997
6-12
Interfaces
●
The command input supports 0 to ±10 Volt signals.
Table 6.10:
Transistor Output Specifications
Parameter
Description
Minimum
Maximum
ON state Voltage
Voltage difference between the external I/O
power supply and the output when the transis-
tor is ON
0 VDC
1.5 VDC
ON state current
Current flow when the transistor is ON
0 mA
50 mA
OFF state Voltage
Voltage difference between the external I/O
power supply and the output when the transis-
tor is OFF
0 Volts
50 Volts
OFF state current
Leakage current from the output when the
transistor is OFF
-0.1 mA
0.1 mA
Figure 6.11
Drive Output Connected to an Opto-Isolator
Figure 6.12
Drive Output Connected to an LED Indicator
Figure 6.13
Drive Output Connected to a Resistive Load
Drive
J1
I/O Pwr
Pin 13
Pin 6
I/O COM
1K
1K
I/O Pwr
Pin 13
Pin 6
Drive
J1
I/O COM
Pin 13
Pin 6
Drive
J1
I/O COM
I/O Pwr
1K