Status display, Status indicator, Error messages – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 179: Run time error codes, Chapter 10, List of run time error codes, E 10-1

Advertising
background image

Publication 1398-5.2 – PDF 1997

Chapter 10

Status Display

Chapter 10

A single front panel indicator displays the status of the drive on a
continuous basis:

The Status LED lights whenever the bus is energized.

Status Indicator

The Status indicator is a three level LED, which indicates the current
operational state of the drive. The status level is indicated by the color
of the LED.

Green = Normal operation

Blinking Green/Orange = Drive Fault

Orange = Hardware malfunction

Blank = Power not supplied or hardware malfunction

Refer to “Troubleshooting” beginning on page 11-3 for
troubleshooting tables.

Error Messages

If there is a fault, the specific error messages may be accessed by
attaching a PC or TouchPad to the ULTRA 100 Series drive. Faults are
detected by the drive in two ways: power-up hardware and run-time
faults. A power-up fault usually requires servicing of the hardware,
while a run-time fault can be cleared by resetting the drive.

“Maintenance and Troubleshooting” lists error codes and possible
actions or solutions to take when resolving the error condition.

Run Time Error Codes

Table 10.1:

List of Run Time Error Codes

Error Code

Fault Description

01 - 03

Reserved

04

Motor Overtemperature, Thermostat

05

IPM Fault (Overtemperature / Overcurrent / Short Circuit)

06 - 08

Reserved

09

Bus Undervoltage

10

Bus Overvoltage

11

Illegal Hall State

12 - 16

Reserved

17

Excessive Average Current

18

Motor Overspeed

19

Excessive Following Error

20

Motor Encoder State Error