Cable Diagrams, Schematics and Examples

B-25

Figure B.25

F- or H-Series Motors to ULTRA 100 Series Drive
using P2 Terminal Strip

Intro

Motor Power Cable

Motor

Motor Power Connector

Encoder Connector

P2

9

101

-13

65-

XXX

Screw Terminal Strip

Enclosure/Cabinet

P1

9101-1391

To

Control

Interface

9101-1392

Screw Terminal Strip

NOTES:

This wiring method provides the option to run cables through a restrictive bulkhead or enclosure.

Cable 9101-1365-XXX has a connectors on the motor end only. The cable connector is molded
and potted to the cable and may not be disassembled. Refer to the schematic for cable 9101-
1366-XXX for information on wiring this cable to the J2 Terminal Strip.

Adaptor Kit 9101-1391 includes the 3 foot cable, screw terminal strip and mounting bracket. The
cable has a 50-pin Mini D ribbon connector at the drive end and a 50-pin D connector at the ter-
minal strip end.

Adaptor Kit 9101-1392 includes the 3 foot cable, screw terminal strip and mounting bracket. The
cable has a 20-pin Mini D Ribbon connector at the drive end and a 20-pin D connector at the ter-
minal strip end.

Motor Power Cables - Use ULTRA 100 Series cables if the CE Mark is required. Other cables
may be used if the CE Mark is not an issue. In either case, the shield on the motor power cable
must be properly grounded at both ends; the shield is grounded at the motor end when the MS
connector is mated.

Clamp exposed motor cable shield
to the chassis ground terminal