Specifications, Appendix g – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 287

Advertising
background image

Publication 1398-5.2 – PDF 1997

Appendix G

Specifications

Appendix G

Agency Approvals

UL and cUL

UL 508C File E145959

CE mark

Low Voltage Directive and
Electromagnetic Compatibility Directive
Certificate of Conformity from TUV Product Service

Environmental

Operating Temperature

0

o

C to 55

o

C (32

o

F to 131

o

F)

Storage Temperature

-40

o

C to 70

o

C (-40

o

F to 158

o

F)

Humidity

5% to 95% non-condensing

Altitude

1500 meters (5000 feet)
Derate 3% for each 300 m above 1500 m (1000 ft. above
5000 ft.)

Vibration

10 to 2000 Hz @ 2g

Shock

15g 11 millisecond half sine

Dielectric Withstanding (Hi-Pot)

Main AC

1414 (1500) VDC for 1 minute, <5mA leakage current

NOTE

:

Metal Oxide Varistors (MOVs) between line and earth ground must be removed when testing.

Internal EMI filter capacitors require testing with DC Voltage.

Weight

1398-DDM-005, -005X

1.7 Kg (3.7 Lbs)

1398-DDM-009, 009X

2.05 Kg (4.5 Lbs)

1398-DDM-019, -019X

2.0 Kg (4.4 Lbs)

Motor Encoder Interface

Signal Output Power

5 Volts DC

Encoder Inputs

A/B, Differential, 26LS33 input, 1 MHz (4 MHz Quadrature)
Maximum Signal Frequency, 1/T Low Speed Measurement

Thermostat Inputs

Normally closed

Hall Inputs

Single-ended, 5 Volt Logic

ABS Input

0 to 5 Volt, 10-bit

User Interface

Serial Port

RS-232 or four wire RS-485,
1200 to 19200 baud

Status Display

3 Level LED

Addressing

Software selected

Digital Inputs

Selectable (4)

12-24 Volt, Optically Isolated, Single ended, Active High, 4.5
mA nominal

ENABLE

12-24 Volt, Optically Isolated, Single ended, Active High, 4.5
mA nominal. Minimum ON time = 1.5 msec.