Appendix B

Cable Diagrams, Schematics and
Examples

Appendix B

Factory supplied cables allow ULTRA 100 Series drives to conform to
the European Union Directives when connecting the drive to motors,
controllers or computers. The following diagrams provide information
on the cables available from the factory.

Refer to Appendix A, “Options and Accessories” for ordering
information.

The information below applies to all factory supplied cables.

Wire Insulation Type: Polyvinyl Chloride

Conductor size: 0.08 mm

2

(28 AWG) tinned copper, except as

noted below.

[0.25 mm

2

(24 AWG) on 9101-1372, 9101-1374 and 9101-1379]

[1.5 mm

2

(16 AWG) on 9101-1190, 9101-1381, 9101-1385 and

9101-1467]

[2.5 mm

2

(14 AWG) on 9101-1191 and 9101-1382]

[6 mm

2

(10 AWG) on 9101-1192 and 9101-1383]

[10 mm

2

(8 AWG) on 9101-1384 and 9101-1399]

[16 mm

2

(6 AWG) on 9101-1193]

Braid Shield Coverage: 85% minimum

Jacket Material: Thermoplastic elastomer

Moldings: 105°C (221°F) Black PVC

Minimum Bend Radius

Control Cables

Motor Power Cables

Connector

mm (in.)

Cable

mm (in.)

Controller (J1)

171.45 (6.75)

9101-1190

91.70 (3.6)

Encoder (J2)

129.54 (5.10)

9101-1191

98.80 (3.9)

9101-1192

156.00 (6.1)

9101-1193

226.80 ( 8.9)

9101-1381

91.70 (3.6)

9101-1382

98.80 (3.9)

9101-1383

156.00 (6.1)

9101-1384

226.80 ( 8.9)

9101-1385

106.70 (4.2)

9101-1399

189.25 (7.5)

9101-1467

91.70 (3.6)

Advertising