8-40

Application and Configuration Examples

13. Choose

Close

to exit the Drive Set Up window.

14. Choose the

Drive

P

arameters

command icon from the Drive

window and then select the

Indexing

tab.

15. Enter the following values for Index 0.

16. Choose

Close

to exit the Drive Parameters window.

17. Verify the Status indicator is green.

18. Select the

I/O

C

onfiguration

command icon from the Drive Win-

dow.

19. Select an appropriate digital input from the pull-down lists avail-

able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:

Start Index

as Input 1

Registration Sensor

as Input 2.

Not Assigned

as Input 3.

Not Assigned

as Outputs 1 and 2.

20. Choose

Close

to exit the I/O Configuration window.

Single Move Settings

Batched Move Settings

Registration

as Mode

Registration

as Mode

8000

as Distance

8000

as Distance

8000

as Registration Dis-

tance

1

as the Batch Count

3

as the Batch Count

0

as Dwell

1000

as Dwell

Appropriate values for
Acceleration and Decelera-
tion

Appropriate values for
Acceleration and Decelera-
tion

Note: The Registration Distance must be longer than the Deceleration
Distance or the move will not be registered.