Connection diagram, Configuration, Analog controller connection diagram – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 116: In figure 8.1 t, Connection diagram configuration

Advertising
background image

Publication 1398-5.2 – PDF 1997

8-2

Application and Configuration Examples

• J1-21 (FAULT RESET) and J1-26 (I/O PWR).

These connections provide manual control for enabling or
disabling the drive and resetting faults. The figure below shows
the jumper, including normally open toggle switches.

6. Connect an external 12 to 24 VDC power source for powering I/O

to J1-5 (I/O PWR) and J1-6 (I/O COM).

7. Connect the drive to a single phase 100-240 VAC, 50/60 Hz power

source.

Connection Diagram

Configuration

Carefully check all connections before entering these parameters.

1. Switch the AC Power to ON and verify:

• Status LED is green. Refer to “Status Indicator” on page 10-1

for an explanation of the display codes.

2. Start ULTRA Master on the PC.

3. Choose

Cancel

from the Drive Select dialog box.

4. Select

P

C Set Up

from the Communications menu in

ULTRA Master to display the personal computer’s communica-
tion settings.

5. Verify the communications port settings of the PC match those of

the drive.

Figure 8.1

Analog Controller Connection Diagram

J1

26 I/O PWR

20 ENABLE

21 FAULT

22 CMND+

23 CMND-

Close to ENABLE Drive

Close to RESET Fault

±10 VDC

DRIVE

L1 3

L2/N 4

Gnd 5

100-240 VAC

50/60 Hz

Single Phase

Power Source

RESET

J5

2 RCV

3 XMT

5 COM

XMT

RCV

COM

TB1

Phase R 6

Phase S 7

Phase T 8

Mtr Gnd 9

J2

Motor

Encoder

External I/O

12-24 VDC

Power Source

5 I/O PWR

6 I/O COM