Not recommended), With 5 vdc to 12 vdc pull-up (not recommended) – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 89

Advertising
background image

Publication 1398-5.2 – PDF 1997

Interfaces

6-25

Figure 6.29

Single-Ended Encoder Interface via Standard TTL Signals
(not recommended)

Figure 6.30

Single-Ended Encoder Interface via Open Collector Transistor
with 5 VDC to 12 VDC Pull-up (not recommended)

twisted pair

twisted pair

Ch B

ENCODER

BX+

BX-

16

J1

Drive

Ch A

AX+
AX-

14

Drive Chassis

Encoder Case

4
2

+5V

Supply
Return

+5 Volts

1

3

+5V

Supply

+5VDC

Connect only if J1 sources Encoder power.

5V @ 250 mA

ECOM

74xx

TTL Output

74xx

TTL Output

Ch I

IX+

IX-

18

74xx

TTL Output

twisted pair

twisted pair

Ch B

ENCODER

BX+

BX-

16

J1

Drive

AX+
AX-

14

Drive Chassis

Encoder Case

Ch A

5-12 Volts

5-12 Volts

4
2

+5V

Supply
Return

ECOM

Ch I

IX+

IX-

18

5-12 Volts

Advertising