Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual

Page 171

Advertising
background image

Publication 1398-5.2 – PDF 1997

Tuning

9-5

Use the default settings if you are uncertain about what values to
enter. The default settings are set to values appropriate to the drive
and motor combination selected during drive initialization.

3. Enable the drive.

4. Choose

S

tart

from the Tuning window. The drive rotates the

motor shaft and then motion will cease. The calculated gains are
displayed and the drive is disabled.

5. Disable the drive manually.

6. Choose

N

ormal Drive Operation

from the Tuning window.

7. Enable the drive.

8. Choose

Close

to exit the Tuning window.

Note: Auto tuning does not have a velocity limit, but it does adhere to
the motor Overspeed setting in the Drive Parameters window.